Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Angelo Po 0N1FR1E Bedienhandbuch

Vorschau ausblenden Andere Handbücher für 0N1FR1E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
Important
The connection must be made by authorised,
skilled personnel, in accordance with the re-
levant legal requirements, using appropriate
and specifi ed materials.
The appliance is supplied with operating vol-
tage 400V/3N (230V/3 available on request)
(for version 0*1FR1E and 1*1FR2E only).
The appliance is supplied with operating
voltage 400V/3N which can be switched to
230V/3 ( for version 0*1FR5E and 1*1FR6E
only).
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows.
If not already present, install a circuit-breaker
1)
(A) with overload cutout and diff erential safe-
ty breaker close to the appliance.
GB
3269930_inst_GB_rev.1

ELECTRICAL CONNECTION

B
A
Open the hatch (B).
2)
Undo the screws (C) to remove the lid (D).
3)
Connect the circuit-breaker (A) to the terminal
4)
board (E) of the appliance as shown in the
diagram and in the electrical system diagram
at the back of the manual.
Use a fl exible cable with at least type H07RN-F
characteristics, rated for an operating tempe-
rature of at least 80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Tighten the cable gland (F).
5)
Replace the lid (D) and fi x it with the screws (C)
6)
on completion of the operation.
Close the hatch (B).
7)
C
E
- 10 -
D
F
ENGLISH

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis