9.1

Maintenance intervals

NOTICE
• The specified maintenance intervals are standard values and refer to single-shift
operation.
• After repeated use, it may not be possible to loosen the welding torch by hand. A suitable
tool is provided to assist with loosening. Do not use pliers to loosen the welding torch.
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection
and testing, as well as any national laws and regulations.
Check the following:
Several times a day
Remove weld spatter from the
torch head. In the case of
heavy weld spatter build-up,
clean during each welding
break.
• Clean the
ABIROB
torch cleaning station.
Then spray with
ABICOR BINZEL anti-
spatter fluid.
• Check sealing rings and
all connections for
damage and to ensure
they are secure. Replace
as needed.
Tab. 12
BAL.0361.0 • 2021-02-25
Weekly
We recommend basic cleaning
once a week. The type and
frequency of cleaning shall be
determined and established by
the operator of the welding
system.
®
torch with a
Optional wire brake
• Check that the piston is in
good working order.
• Clean the wire brake once or
twice, depending on the wire
quality.
• Check the neckliner for dirt.
Clean or replace as needed.
• Clean the welding torch and
cable assembly interface
contact surfaces, as well as
threaded connections at least
once (depending on the
amount of dirt and debris
present).
Maintenance intervals
9 Maintenance and cleaning
Monthly
• Check that the
connections (cable
assembly, control lead,
ground) are secure.
Tighten if necessary.