30/32
Troubleshooting and Resolution
Bosch Rexroth AG, MIT: PE 2, 3 842 358 722/2015-05
15 Troubleshooting and Resolution
• If you are unable to remedy the error, please get in touch with one of the contact
addresses listed at www.boschrexroth.com.
16 Technical Data
• For dimensions, see the sales catalog TS 2plus, 3 842 531 138.
• Maximum load/section load: 30 kg, 1.0 kg/cm section length
• Noise emissions: < 70 dB(A)
16.1 Ambient conditions
• The transfer systems have been designed for stationary use in a location that is
protected from the elements.
• Operating
+5°C to +40°C
temperature
–5°C to +60°C with 20% reduced load
• Storage temperature –25°C to +70°C
• Relative humidity
5% to 85%
• Air pressure
> 84 kPa, appropriate height < 1400 m above sea level
• Permissible fl oor load: 1000 kg/m
• Load values are reduced by 15% when the system is set up in a location with an
altitude > 1400 m.
• Avoid molds, fungi, rodents, and other vermin.
• Do not install or operate near industrial systems with chemical emissions.
• Do not install or operate near sandy or dusty sources.
• Do not install or operate in areas that are regularly jarred by high forces caused by
e.g. presses or heavy machinery.
• Resistant to many common media used in production such as water, mineral oil,
grease, and detergents. Contact your Rexroth representative if you have any doubts
about resistance to specifi c chemicals, such as test oil, doped oils, aggressive
detergents, solvents, or brake fl uid.
• Avoid long-term contact with acidic or basic reacting materials.
2