Secondary Device Functions (continued)
Statistics Data Output: Status
Bit
Meaning
position
0
Configured
1
Started min/
max/avg
2
Started moving
average
3
Buffer Overflow
Event
4
Timeout Event
5
Reserved
6
Reserved
7
Reserved
Tab. 5-29: Statistics Data Output – Status
5.5.5
System Commands
Command Value Device Action
0xA7 (167)
Statistics Reset – Resets all output
parameters to 0 and all user
settings to the default values.
0xA8 (168)
Statistics Start min/max/avg –
Starts the statistics of the minimum
value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop – Stops statistics
operation completely.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving
average calculation.
Tab. 5-30: Basic statistics – System Commands
For an overview of all System Commands, see section 3.5
on page 19.
60
english
Description
1 – all inputs are configured
1 – min/max/avg running
1 – moving average
running
1 – buffer overflow
1 – the set time for the
minimum value/maximum
value/average calculation
has elapsed