Overview of IO-Link Data and Functions (continued)
Event Code
Event Type
0x8D08
Warning
(36104)
0x8D09
Warning
(36105)
0x8D0B
Warning
(36107)
0x8D0D
Warning
(36109)
0x8D0E
Notification
(36110)
0x8D10
Warning
(36112)
0x8D12
Warning
(36114)
0x8D13
Warning
(36115)
0x8D15
Warning
(36117)
0x8D20
Warning
(36128)
0x8D22
Warning
(36130)
0x8D23
Error
(36131)
0x8D24
Warning
(36132)
0x8D25
Error
(36133)
0x8DC0
Notification
(36288)
Tab. 3-4:
Events – Overview
www.balluff.com
Description
Speed value is below the limit.
Speed value is above the limit.
Overload or short circuit at pin 2
► Check wiring.
Incorrect load/cable breakage, analog current output
pin 2
► Check wiring or connected devices.
The time has elapsed. This event reports the timeout
of the minimum value/maximum value/average
calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it
does not indicate the end of the calculation.
Device temperature upper warning – The set upper
temperature warning threshold has been exceeded.
The defined threshold of the device-internal humidity
was exceeded.
► Check installation and ambient conditions.
One or more extreme conditions present.
Overload at pin 2
► Check wiring.
Device temperature lower warning – The set lower
temperature warning threshold is below the minimum
value.
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
Write cycle limit reached – saving no longer ensured
– replacement recommended.
Parameter write error – for information purposes
only.
Parameters not consistent – basic settings are used,
service required.
Teach-in timeout – The current teach process took
too long and was interrupted.
Device Status
0 – Device is operating properly.
0 – Device is operating properly.
2 – Out-of-Specification
2 – Out-of-Specification
0 – Device is operating properly.
0 – Device is operating properly
1 – Maintenance-Required
0 – Device is operating properly.
2 – Out-of-Specification
0 – Device is operating properly
0 – Device is operating properly
1 – Maintenance-Required
0 – Device is operating properly
4 – Failure
0 – Device is operating properly.