Overview of IO-Link Data and Functions (continued)
Name
Index
Process Data Profile
0x0051
selection
Process Data Input
0x000E
Descriptor
Process Data Output
0x000F
Descriptor
Last Valid Process
0x0028
Data Inputs
Last Valid Process
0x0029
Data Outputs
Profile Characteristic
0x000D
Device Access Locks
0x000C
Tab. 3-2:
ISDU – Identification Data
3.5
System Commands
Command Value
Device Action
0x40 (64)
Teach Apply – Calculates the switching point for SP1, SP2.
0x41 (65)
Teach SP1 – Determines teach point 1 for setpoint 1 and calculates the switching point.
0x42 (66)
Teach SP2 – Determines teach point 1 for setpoint 2 and calculates the switching point
0x43 (67)
Teach SP1 TP1 – Determines teach point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2 – Determines teach point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1 – Determines teach point 1 for setpoint 2
0x46 (70)
Teach SP2 TP2 – Determines teach point 2 for setpoint 2
0x47 (71)
Teach SP1 Start – Starts dynamic teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop – Stops dynamic teach-in for setpoint 1 and calculates the switching point.
0x49 (73)
Teach SP2 Start – Starts dynamic teach-in for setpoint 2
0x4A (74)
Teach SP2 Stop – Stops dynamic teach-in for setpoint 2 and calculates the switching point
0x4E (78)
Teach Reset – Any active teach-in process is interrupted, all temporarily stored values are reset.
0x4F (79)
Teach Cancel – Any active teach-in process is interrupted.
0x80 (128)
Device Reset – Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values.
0x81 (129)
Application Reset
0x82 (130)
Reset Factory Settings
0xA5 (165)
Maintenance Reset
0xA6 (166)
Switching Counter Reset – Resets counter value and flags.
0xA7 (167)
Statistics Reset – Resets all output parameters to 0 and all user settings to the default values.
www.balluff.com
Subindex
Access
Process Data Information and Configuration
0
R/W
(81)
0
R
(14)
0
R
(15)
0
R
(40)
0
R
(41)
Profile Characteristic
0
R
(13)
Device Access Locks
0
R/W
(12)
Length
Data Type
1 byte
ENUM
= PD input
UINT8[]
data length
= PD output
UINT8[]
data length
Variant 1/2:
Special
1 byte
Variant 3:
17 bytes
Variant 4:
6 bytes
1 byte
Special
18 bytes
UINT16[]
2 bytes
UINT16
Data
Default
Storage
Yes
[0]
n/a
n/a
Yes
0
english
19