4.4.5 Analog value at start position / Analog value at end position
The active analog measuring range can be defined within the maximum values via the
two parameters Analog value at start position and Analog value at
end position. Depending on the set "Operating mode analog output"
(chapter: 4.4.1), the values must be entered in [mV] or in [µA]. The Analog value
at start position can also be selected larger than the Analog value at end
position.
Figure 12: Start position < end position, rotation = CW; counting direction = increasing
Figure 13: Start position > end position, rotation = CW; counting direction = increasing
Legend
A
O
A
max
A
min
ML
Pos
Start-Pos = programmed Analog value at start position (voltage* / current)
End-Pos
* signed
Printed in the Federal Republic of Germany
07/31/2020
= actual measured Analog output quantity (voltage* / current)
= positive maximum value of the analog output quantity (voltage* / current)
= negative maximum value of the analog output quantity (voltage* / current)
= maximum value (steps / speed*)
= actual Position or Speed* of the measuring system
= programmed Analog value at end position (voltage* / current)
TR - ECE - BA - DGB - 0162 - 00