Fig. 8: Replacement of filter element in filter
Filter
AF0056
16.5. Check of safety valve
Disassemble the cabinet cover before the safety valve check and reassemble it afterwards. (see
chap.16.9)
When the compressor is operated for the first
time, make sure that the safety valve is working
properly.
Turn screw of safety valve several
rotations to the left until the safety valve
releases air.
Let the safety valve blow out for only a
few seconds.
Turn screw to the right until it seats,
closing the valve.
Risk of pressure increase when safety valve is damaged.
Safety valve must not be used to depressurize the air tank. It could damage the
safety valve function. The valve is set to the maximum allowed pressure, it is
tested and marked.
Safety valve setting must not be adjusted.
Risk of injury when compressed air is vented.
Protect your eyesight when checking the safety valve – wear protective
goggles.
NP-DK50-10SM-4_01-2020
Article no.
025200303-000
Filter element
CARTRIDGE 06050
26
PRODUCT MAINTENANCE
Article no.
025200304-000
Fig. 9: Check of safety valve