1.

TECHNICAL DETAILS

GB
Power supply
Absorption
Fuse F1
Thrust
Max stroke
Max load
Opening speed
Closing speed
Service class
Intermittence
Temperature
Degree of protection
Control Panel
2.
REFERENCE ILLUSTRATIONS AND ACCESSORIES
The given operating and performance features can only be gua-
ranteed with the use of DITEC accessories and safety devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Drive unit
[3]
Retention bracket
[4]
Slide
[5]
Release cord
[6]
Guide
[7]
Guide coupling
[8]
Transmission
[9]
Photocells
[10] Sensitive edge
[11] Transmitter support
[12] Connect the power supply to an omnipolar switch with contact opening
distance of at least 3 mm (not supplied by us) or by means of power plug.
Connection to supply mains must be carried out in an independent ra-
ceway separate from control connections and safety device connections.
2.2 Accessories
BATK1
Battery kit
GLOBEC
Adapter for up and over doors with counterweights
ASB1
External release kit with cord and lock L=900 mm
ASB2
Cord release device L= 2000 mm
GLOBEL
Extension set for 1120 mm chain
GLOBELV Extension set for 1120 mm belt (for steel guide only)
GLOBEFM Additional close stop
GLOBESI
Intermediate support
GLOBEGF Iron track L=3000 mm
GLOBEGA Aluminium track L=3000 mm
3.

INSTALLATION

3.1 Chain type GLOBE assembly (fig. 4)
-
Extend the chain.
-
Fit the coupling [1] as far as the guide stop. Fit the guide [2] as
far as the stop. Fit the coupling [3] as far as the guide stop [2].
-
Superimpose the guide [4] on the coupling [3], correctly fit
the transmission in the guide [4]: lift the guide as shown in
the detail to permit fitting the transmission.
-
Move the coupling [3] towards the transmission as far as
the guide stop [4].
Note: the guides must be fitted in a specific direction (see stops
[x] shown in illustration).
GLOBE - IP1839
GLOBE7
230 V~ / 50-60 Hz
0,7 A
F1,6A
500 N
2500 mm
7 m²
0,15 m/s (chain)
0,18 m/s (belt)
0,10 m/s (chain)
0,12 m/s (belt)
3 - FREQUENT
S2 = 30 min / S3= 50%
-20° C / +55° C
IP10
70R
GLOBE7J
120 V~ / 50-60Hz
1,4 A
F3,15A
500 N
2500 mm
7 m²
0,15 m/s (chain)
0,18 m/s (belt)
0,10 m/s (chain)
0,12 m/s (belt)
3 - FREQUENT
S2 = 30 min / S3= 50%
-20° C / +55° C
IP10
70R
3.2 Belt type GLOBE assembly (fig.5)
-
(fig. 5a) Fit the belt to the transmission and slide.
-
(fig. 5b) Fit the belt stop as shown in the illustration.
-
(fig. 5c) Fasten the two ends of the belt to the release pin
by means of the couplings keeping to the pin direction
shown in the illustration.
-
(fig. 5d) Fit the drive pin (belt - transmission - slide) in the guide.
-
(fig. 5e) Pass the belt around the pulley and secure by
means of the pin [Y]. Fit the guide as shown in fig. 3, lock
in the drive unit as far as the stop and tighten screw [K].
-
(fig. 5f) Push the transmission towards the outside of the
guide and fasten the retention bracket to the wall.
3.3 Chain or belt tensioning (fig.6)
-
Correct tensioning is achieved by leaving 1÷2 mm between
the spring retainer [E] and stop [H] to enable the spring [E]
to work in the best possible way.
Attention: over-tightening could affect proper operation of the
automatic system.
3.4 GLOBE installation (fig. 7-8)
-
Establish and trace the retention point of the guide on the
wall and ceiling (fig. 7a).
Attention: in the case of spring balanced up and over doors with
counterweights use GLOBEC (fig. 7b). With the off-board drive
unit, fit the guide to the wall using the transmission bracket (fig. 7c).
(fig. 7d) Fit the bracket [3] and secure using the screws
provided. Lift the unit and bend the brackets to measure (if
necessary eliminate the excess parts), then fasten to the ceiling.
Attention: (fig. 8) to fully open sectional doors with special
heights, the arm [M] can be shortened and the coupling point
[L] can be moved from 20 mm to 100 mm further in than [G].
If necessary, fit a shim [J] (not supplied by us, max 200 mm)
between the wall and the tightener [L]. This way the stroke of the
slide will be increased by exploiting all the available guide.
-
Manually release (see OPERATING INSTRUCTIONS)
and move the slide up to the closed door, then fit the re-
tention bracket [G] on the top edge, possibly interposing
the supplied reinforcing angular [P] (fig.8c-d); afterwards,
re-lock the slide by moving the door manually.
-
(Fig. 9) Fit the stop in the guide and secure in the desired
opening position.
-
(Fig. 10) For stronger fastening the intermediate support
GLOBESI can be installed.
18
GLOBE10
230 V~ / 50-60 Hz
1,2 A
F1,6A
900 N
2500 mm
10 m²
0,12 m/s (belt + 71RC1)
0,15 m/s (chain)
0,18 m/s (belt)
0,10 m/s (chain)
0,12 m/s (belt)
3 - FREQUENT
S2 = 30 min / S3= 50%
-20° C / +55° C
IP10
71R (71RC1)