Note
If the potentiometer for engine speed (see chapter6.11 Op-
erating consoles) is not in the end position (0), then a dis-
play will appear.
If this display appears, turn the potentiometer for
engine speed anticlockwise to the end position (0).
Working mode
In WORKING MODE, it is possible to choose between 3
options. These options influence the engine speed and hy-
draulic power.
30/60 l/min
The engine speed is limited to a max. 1600 rpm, and the
hydraulic power to 30 l/min, if the hydraulic PTO selector
switch is at 50 l/min.
The engine speed is limited to a max. 1600 rpm, and the
hydraulic power to 60 l/min, if the hydraulic PTO selector
switch is at 100 l/min.
40/80 l/min
The engine speed is limited to a max. 2200 rpm, and the
hydraulic power to 40 l/min, if the hydraulic PTO selector
switch is at 50 l/min.
The engine speed is limited to a max. 2200 rpm, and the
hydraulic power to 80 l/min, if the hydraulic PTO selector
switch is at 100 l/min.
50/100 l/min
Maximum hydraulic power and maximum engine speed.
Note
The selected setting is also kept when switching over be-
tween WORKING MODE AND CREEPING MODE.
When switching over to TRANSPORT MODE, the setting
is reset and the engine goes to idle speed.
After an option has been selected, the relevant display will
appear on the display (bottom right).
Changing to the option selection increases or reduces the
current speed, unless the engine is in idle mode.
Press the function button to return to the option se-
lection.
64
Illustration: Selected maximum speed = 1600 rpm and cur-
rent speed 1500 rpm (engine is running)
The selected speed is displayed in the from of a small, yel-
low arrow. The idle speed is always 950 rpm (minimum
speed).
The yellow needle indicates the current speed.
Illustration: Idle speed 950 rpm and current speed = 0 (en-
gine off)
6.9
Foot room with pedals
Accelerator pedal
1
Brake pedal
2
Steering wheel inclination adjustment pedal
3
Inching pedal
4
Brake fluid container
5
MIC 50 MDC variant (mechanically controlled drive)
English