5.3 PULSE A - TOTAL OPENING
Terminals "14-16". (Circuit Normally Open). The status of this input is signalled by LED 3. This circuit is connected to any device
(e.g. button, radio control, etc.) which, when a contact is closed, generates a gate opening and/or closing pulse.
Note: To install multiple pulse devices connect the contacts in parallel.
5.4 PULSE B - PARTIAL OPENING
Terminals "14-17". (Circuit Normally Open). The status of this input is signalled by LED 4. This circuit is connected to any device
(e.g. button, radio control, etc.) which, when a contact is closed, generates a gate opening and/or closing pulse. The
opening motion is performed for a fixed time of 10 seconds.
Note: To install multiple pulse devices connect the contacts in parallel.
5.5 CLOSING PROTECTION PHOTOCELLS
Terminals "18-19" (Circuit Normally Closed). The status of this input is signalled by LED 5. This circuit is connected to any safety
device (photocells, pressure switch, detector, etc.) which, when a contact is opened, acts as a safety on the closing motion.
The effect will vary depending on the settings performed using dip-sw 4.
Note: To install multiple safety devices connect the NC contacts in series.
Note: If no safety devices are being used, jumper connect the input.
It is possible to prevent the gate from closing by connecting a 24h timer in series to the closing photocell circuit.
6. TERMINAL BOARD M5 (LOW VOLTAGE) CONNECTIONS - DESCRIPTION
6.1 OPENING LIMIT SWITCH
Terminals "20-21" (Circuit Normally Closed). The status of this input is signalled by LED 6. This circuit is connected to the opening
limit switch.
6.2 CLOSING LIMIT SWITCH
Terminals "21-22" (Circuit Normally Closed). The status of this input is signalled by LED 7. This circuit is connected to the closing
limit switch.
WARNING: In case of wrong or missing connection of the limit switch, the control unit will be inhibited and will signal this status
by the fast flashing of the diagnostic LED 1.
6.3 ACCESSORY POWER SUPPLY
Terminals "23-24". (24 V~). WARNING: the max. load for the accessories is 500 mA.
The unit is designed to house a single-channel radio-receiver module. To install the module, cut off the electric power supply
and insert the module into the special connector M6 inside the unit.
Then follow the instruction coming along with the radio-receiver to store the remote control settings.
LEDS
2 - Stop
3 - Pulse A
4 - Pulse B
5 - Photocells
6 - Opening limit switch
7 - Closing limit switch
Note: Bold is used to indicate the led condition with the gate at rest.
9.1 PAUSE
To adjust the pause duration (for automatic operation), use trimmer "B". The duration can be adjusted from 0 to 120 seconds.
9.2 OPEN/CLOSE
To adjust the duration of the gate opening/closing time, use trimmer "C". The duration can be adjusted from 12 to 120
seconds. Note: To obtain maximum system efficiency, adjust the opening/closing time so that the electric motor can be fed
for a few seconds after the gate has reached the limit switch.
7. INSERTING THE REMOTE CONTROL RECEIVER BOARD

8. CONTROL LEDS

ON
Control deactivated
Control activated
Control activated
Safety devices disabled
Limit switch free
Limit switch free
9. ADJUSTMENTS WITH TRIMMER
OFF
Control activated
Control deactivated
Control deactivated
Safety devices enabled
Limit switch occupied
Limit switch occupied
6
LED 1
Diagnostic
Slow:
Correct operation
Fast:
Failure in the limit switch circuit