Herunterladen Inhalt Inhalt Diese Seite drucken

Switching Off; Warnings; Safety Features; Maintenance Schedule - SDMO iNEO 1000 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
4.2. Operation
When the generating set is warm and the running speed has stabilised (after approximately 3 minutes):
n
Check that the operating light is turned on (fig. A – no. 11, A).
o
Activate the "
M
M
A
A
X " or "
X
p
Connect the devices to the generating set sockets (fig. A – no. 8).
In case of overload or short-circuit, the operating light (fig. A – no. 11, A) switches–off and the overload indicator (fig. A – no. 11, B)
glows: Stop the generating set and eliminate the overload.
4.2.1 MAX-ECO mode

4.3. Switching off

n
Shut down and disconnect the devices.
o
Allow the engine to run idle for 1 or 2 min.
p
Set the fuel tank aeration pointer to
q
Close the fuel tap (fig. A – no.3).
The generator set comes to a stop.
Always ensure suitable ventilation for the generating set.
Even after shut down, the engine continues to dissipate heat.
Warning

5. Safety features

5.1. Oil cut-out
If there is no oil in the engine sump, the oil safety mechanism automatically stops the engine to prevent any damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.

6. Maintenance schedule

6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
6.2. Maintenance table
Operations to be carried out
Component
on reaching the 1
Generating set
Check the level
Engine oil
Fuel strainer
Air filter
Spark plug
Check and clean
Valves*
* These operations must be entrusted to one of our agents
If used occasionally only, drain-out the engine oil at least once a year.
E
E
C
C
O " mode (fig. A – no. 9).
O
O
F
F position (fig. A – no. 4 & fig. C – no. 1).
O
F
F
With each usage
st
due date
Cleaning
Renew
Cleaning
Checking
Cleaning
Checking*
Fig. A – no. 9
MAX
When the button is in the "
large inrush current (at no load, it rotates at 5000 rpm).
ECO
The "
E
C
O " position is useful for smaller loads. Between 0 and 400W, the
E
C
O
generating set consumes less and is quieter (at no load, it rotates at
4000 rpm).
From a load demand of 400W, the operating speed is the same whatever
the position of the MAX-ECO button.
Every month
Or Every 10 hours
M
M
A
A
X " position, the generating set can react to a
X
Every 3 months
Or Every 50 hours
Every year
Or Every 300 hours

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis