  • DEUTSCH, seite 59
Fault
The pilot light goes out.
The pilot light ignites but the
burner remains off.
The flame is yellow.
The appliance does
not heat up.
The control panel does not
come on
TABLE OF ALARM INDICATIONS
Alarm
EO
EOC
E2
AL1
Causes
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Contactor not receiving power or
faulty.
Electronic circuit board not
receiving electrical power.
Cause
Sensor has short-circuited;
electrical connection faulty.
Electronic control device faulty.
Loss of data set on the electronic
circuit board.
The maximum permitted
temperature values have been
exceeded; break in sensor
circuit.
- 17 -
Remedies
Make more attempts to light the
flame.
Check the condition of the
thermostat and activate any
ignition enabling device.
Information
Contact the after-sales
service..
Check the thermostat and activate
any start-up enabling device.
Check or replace the contactor
coil.
Check or swap the phase wire
connections.
Remedy
Information
Contact the after-sales
service..
Information
Contact the after-sales
service..
Switch the appliance off and
back on; if the problem persists,
call the after-sales service
Wait for the oil to cool down; if
the problem persists, call the
after-sales service.
IT
GB
DE
FR
ES
English

Werbung

Inhaltsverzeichnis
loading