D1 D2 Parameter
C
0
Number of operators
1
Operator 1 turning direction
(also changes operator 2)
2
Operator 2 turning direction
(also changes operator 1)
3
Type of gate
4
O p e n i n g
s a f e t y
(photocell)
5
Closing safety device (photocell)
Closing photocell with C520 or
C521, also prevents the start of
gate opening
6
Electrolock / electromagnet
C630 and C640 are used to
manage an external relay at
24Vdc, connected to cable
c o n n e c t o r s P 1 1 - P 1 2 . T h e
e l e c t r o m a g n e t
externally supplied (through this
relay) and sized in line with the
electromagnets used.
7
Encoder / Limit switches
The connections depend on the
type of operator selected (C301,
C 3 0 2 o r C 3 0 3 ) ; s e e t h e
corresponding wiring diagram
8
Radio card
9
Safety strip
A
Slowdown
P
1
T o t a l
o p e n i n g
programming
2
P e d e s t r i a n o p e n i n g r a d i o
programming
3
Gate travel programming
F
1
Key command using ST1 and
ST2 pushbuttons.
With F101 the gate (total or
pedestrian) can be kept open by
keeping ST1 or ST2 pressed
down respectively. This allows
the time scheduler to be used in
combination with F2 and/or F4
K 00.
2
Semi-automatic or automatic
operation mode and stand-by
time (in seconds) in automatic
mode
3
Pedestrian opening (%)
4
Pedestrian closing mode
Complete programming chart (I)
D3
D4
0
1, 2
0
1, 2
0
1, 2
0
1 ... 3
0,1
0,1
d e v i c e
0...2
0,1
0...4 0...4
m u s t
b e
0
0...4
0
1, 2
0
1, 2
0
0...3
o
ç
r a d i o
o
ç
o
ç
0
0...4
0..5. 0...9
0...9 0...9
0...5 0...9
Preset
Options or values
option
01
01: one operator,
02: two operators (only available with C301)
01
01: direction A, 02: direction B. Check direction by
pressing ST1 (open) and ST2 (close)
01
01: direction A, 02: direction B. Check direction by
pressing ST1 (open) and ST2 (close)
01
01: swing, 02: sliding, 03: up-and-over
00
00: not installed,
10: no testing, 11: with testing
00
00: not installed,
10: no testing,
11: with testing,
20: no testing,
21: with testing
00
00: not installed
1X: electrolock
Programmable electrolock time: 3 seconds
with X=0 (default), 3.5s with X=1, 4s with X=2,
4.5s with X=3, 5s with X=4.
2X: electrolock
Programmable time (electrolock/motor
reverse): 4.5/1.5 seconds with X=0 (by default),
5/2s with X=1, 5.5/2.5s with X=2, 6/3s with
X=3, 6.5/5s with X=4.
30: electromagnet without impulse
40: drop electromagnet
00
00: not installed; 01: with single encoder;
02: with limit switches;
03: with dual encoder;
04: with encoder and ends of travel (not available
with C301 selected);
02
01: RSD card (non-decoding);
02: two channel decoder card
01
01: mechanical; 02: resistive 8k2
01
00: no slowdown;
01: slowdown in opening and closing;
02: slowdown in opening;
03: slowdown in closing
Programmes total opening code and channel
Programmes pedestrian opening code and channel
Programmes the operations in accordance with
configuration CA
01
00: ST1 and ST2 without effect, key commands are
made by radio (channel 1: total opening-
closing, channel 2: pedestrian opening-closing)
01: ST1 total opening-closing, ST2 pedestrian
opening-closing
02: ST1 total opening, ST2 total closing
03: dead-man mode (the display shows HP.);
04: dead-man mode in closing
00
00: semi-automatic mode
01: automatic mode and stand-by time 1 second;
...
59: automatic mode and stand-by time 59 sec.;
1.0: 1 min. 0 sec.;
...; maximum 4 minutes
40
00: pedestrian opening is not carried out,
10: 10% of total opening, etc
00
00: semi-automatic mode
01: automatic mode and stand-by time 1 second;
...
59: automatic mode and stand-by time 59 sec.;
1.0: 1 min. 0 sec.;
...; maximum 4 minutes
without
reverse
impulse.
with
reverse
impulse.
23