Calibration for QS-carburetor:
Main jet
- 5° Celsius
+ 5° Celsius
+15° Celsius
+25° Celsius
+35° Celsius
Table 1A
Main jet
- 41° Fahrenheit
+ 41° Fahrenheit
+ 59° Fahrenheit
+ 77° Fahrenheit
+ 95° Fahrenheit
Table 1B
 Attention: A smaller main jet than shown in the table could lead to piston seizure under the
existing conditions.
 Note:
At engine operation with ambient temperature below 10 °C / 50°F make sure not to
demand full power before the coolant temperature has reached 45 °C / 113°F.
 Note:
The warranty by BRP-Powertrain will no longer apply, if the carburetor calibration is
wrong and causes an engine damage.
Calibration for XS-carburetor:
These values were not set at editorial deadline. If needed, please contact your authorized ROTAX
distributor or one of his service centers.
For better understanding and as help for carburetor adjustment the following figure describes the
effect of the various adjustments, depending on throttle position.
Seite/page 83/98
Operators Manual 125 MAX DD2 evo
altitude
altitude
0 Meters
400 Meters
215
210
210
205
205
200
200
195
195
190
altitude
altitude
0 Feet
1300 Feet
215
210
210
205
205
200
200
195
195
190
altitude
altitude
800 Meters
1200 Meters
205
200
200
195
195
190
190
185
185
180
altitude
altitude
2600 Feet
3900 Feet
205
200
200
195
195
190
190
185
185
180
Ausgabe/edition 11/2014
altitude
1600 Meters
195
190
185
180
175
altitude
5200 Feet
195
190
185
180
175