6-2-3. MMS STATUS indicator
Indicator condition
Off
Blinking light
Red
Green
Orange
Steady light
Green
Orange
6-2-4. Rear STATUS indicator
Indicator condition
Off
Blinking light
Green
Orange
Red (With buzzer)
Red (Without buzzer)
Steady light
Green
Orange
Red
Projector condition
Multi-media switcher (MMS) not in use.
Link error
Preparing link with Built-in multi-media
switcher (MMS).
Preparing link with External multi-media
switcher (MMS).
Built-in multi-media switcher (MMS) is linked.
External multi-media switcher (MMS) is linked.
Projector condition
Main power is off.
The projector is getting ready to turn on.
The douser is closed.
The projector is cooling down.
Safety problem, error
Error with possible image project under certain
conditions.
The projector is turned on.
The projector is in standby.
Error at a level with not affect on projection.
6. Appendix
Note
-
Link error. An error message is
displayed in the LCD screen.
Check the content of the error.
Wait for a moment.
Wait for a moment.
-
-
Note
-
Wait for a moment.
Wait for a moment.
An error message is displayed in
the LCD screen.
Check the content of the error.
-
-
An error message is displayed in
the LCD screen.
Check the content of the error.
39