Technical Data; Disposal - Grundfos MAGNA UPE 2000 Series Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für MAGNA UPE 2000 Series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25

10. Technical data

Supply voltage
1 x 230-240 V –10%/+6%, 50/60 Hz.
Motor protection
The pump requires no external motor protection.
Enclosure class
IP 44.
Insulation class
H.
Relative air humidity
Maximum 95%.
Ambient temperature
0°C to +40°C.
Temperature class
TF110 to EN 60 335-2-51.
Liquid temperature
Maximum +110°C.
Continuously: +15°C to +95°C.
Pumps in domestic hot-water systems:
Continuously: +15°C to +60°C.
To avoid condensation in the terminal box and the
stator, the pumped liquid temperature must always
be higher than the ambient temperature. See the ta-
ble below:
Ambient
Liquid temperature
temperature
Min. [°C]
[°C]
15
15
20
20
25
25
30
30
35
35
40
40
Maximum system pressure
The maximum system pressure is indicated on the
pump flanges: PN 6 / PN 10: 10 bar.
Number of bolt holes in the pump flange: 4.
Inlet pressure
Recommended inlet pressures are stated in the
following table:
Liquid temperature
Pump type
75°C
[bar]
MAGNA UPE/UPED
24
EMC (electromagnetic compatibility)
EN 61 800-3.
Sound pressure level
The sound pressure level of the pump is lower than
54 dB(A).
Leakage current
The pump mains filter will cause a discharge current
to earth during operation. I
Pump inputs and outputs
Signal output
Input for external
start/stop
Inputs of pump with GENI module
Inputs for max.
and min. curves
Input for analog
Max. [°C]
0-10 V signal
95/110
95/110
95/110
Bus input
95/110
90/90
70/70
Input of pump with LON module
Bus input

11. Disposal

Disposal of this product or parts of it must be carried
out according to the following guidelines:
1. Use the local public or private waste collection
90°C
2. In case such waste collection service does not
[bar]
0.15
0.45
leakage
Internal potential-free change-
over contact.
Maximum load:
250 V, 2 A AC1.
Minimum load: 5 V, 100 mA.
Screened cable.
External potential-free switch.
Contact load: 5 V, 10 mA.
Screened cable.
Loop resistance:
Maximum 130 Ω.
External potential-free switch.
Contact load: 5 V, 1 mA.
Screened cable.
Loop resistance:
Maximum 130 Ω.
External signal: 0-10 VDC.
Maximum load: 1 mA.
Screened cable.
GRUNDFOS bus protocol,
GENIbus protocol, RS-485.
Screened cable.
Wire cross section:
0.25 - 1 mm².
Cable length:
Maximum 1200 m.
LonTalk
protocol, FTT 10.
Twisted-pair cable.
Wire cross section: 0.25 - 1 mm².
service.
exist or cannot handle the materials used in the
product, please deliver the product or any haz-
ardous materials from it to your nearest GRUND-
FOS company or service workshop.
Subject to alterations.