Herunterladen Inhalt Inhalt Diese Seite drucken

Inserting The Cover Plate; Mounting The Adsorber - Bosch TTM 2104 Erstinbetriebnahme

Reifenprofilmessgerät
Vorschau ausblenden Andere Handbücher für TTM 2104:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en |
30 | TTM 2104 | Installing the system
3.2.4

Inserting the cover plate

Insert cover plate with the 4 bolts into the semi-
circular holes in the edge protection frame. The
cover plate must rest uniformly without clearance.
Fig. 15:
Measuring unit with open cover plate
1 Locating pin
2 Cover plate
3 Semi-circular hole, rear
4 Semi-circular hole, front
3.2.5

Mounting the adsorber

1. Open the measuring unit cover plate.
The cover plate stays open by itself after it has been
turned by approx. 110°.
2. Remove the measuring unit equalizer valve.
Fig. 16:
Equalizer valve
3. Check the color of the drying agent (the color of the
drying agent must be orange; see Fig. 19).
|
1 691 206 006
2017-10-16
4. Unscrew protective cap of the drying agent
adsorber.
Fig. 17:
Unscrewing the protective cap
1 Protective cap
2 Adsorber
5. Screw the adsorber into tapped hole of the
diagnostic module.
Fig. 18:
Position adsorber
1 Diagnostic module
2 Edge protection frame
3 Adsorber
6. Remove adsorber's red protective backing.
!
Do not remove protective backing until
commissioning.
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis