26 | TTM 2104 | Information on installation location
2.3.2

System

Fig. 2:
Dimensions TTM 2104
1 "Master" measuring unit
2 Wireway
3 "Satellite" measuring unit
i
When installing TTM 2104 in the vicinity of a working
pit, observe the following:
- The pit width defines the distance to the two
measuring units. A distance which exceeds the
specified 745 mm must be documented in the
installation report.
- cable according to wiring diagram B.
- install electrical cabinet in the working pit.
- route connection cables and feeder (customer) to
the working pit.
(on both sides of the pit: provide drill holes to the
diameter of the wire plug).
2.4

Wiring diagram

i
The connecting cables to the electrical cabinet
(10 m) included in the scope of delivery must not be
extended.
i
The feeder to the electrical cabinet must be
executed by the customer.
2.4.1

Wiring diagram A (standard)

Only the "Master" measuring unit is connected to the
network. The "Satellite" measuring unit is connected to
the "Master" measuring unit.
|
1 691 206 006
2017-10-16
Fig. 3:
Wiring diagram A
1 PC (optional: Digital Signage)
2 Electrical cabinet
Fig. 4:
Wiring diagram A: "Satellite" measuring unit
1 "Satellite" measuring unit connection cable
2 "Satellite" measuring unit data cable
3 Connection to the "Master" measuring unit
Fig. 5:
Wiring diagram A: "Master" measuring unit
1 "Satellite" measuring unit data cable
2 "Satellite" measuring unit connection cable
3 "Master" measuring unit data cable
4 "Master" measuring unit connection cable
5 Connection to the electrical cabinet
6 Connection to the PC
Robert Bosch GmbH

Werbung