10. Troubleshooting Procedures

10.1 Startup faults

Malfunction
Malfunctioning monitoring device (IPM 12,
and Mobile-PGA 3
No pulses, faulty readout of actual values.
Gears not running smoothly.
Gears jammed
Cause
Supply of voltage to monitoring unit too high or
too low.
NAMUR switch improperly connected or
defective.
Monitoring unit IPM 12 defective.
Particles of dirt in gear chamber.
Differential pressure over low meter too low.
Particles of dirt in gear chamber,
Outlet port blocked.
10. Troubleshooting Procedures Maintenance
Remedy
See operating instructions for "VARIOLUB
monitoring system for low meter lubrication
systems" 951-130-300 (PGA 3), Chapter 6.
See operating instructions for "VARIOLUB"
monitoring system for low meter lubrication
systems" 951-130-300 (PGA 3), Chapter 6,
Check NAMUR switch, Chapter 7.21 (8.2.1)or
Check IPM 12 - Hardware test, Chapter 9..1
(11.1)
Clean gear chamber, cf. Chapter 9.1 "General
remarks" and Chapter 9.7.
Increase pressure.
Clean gear chamber, cf. Chapter 9.1 "General
remarks" and Chapter 9.7.
Check tubing, ittings and couplings.