SKF SMD series Handbuch Seite 67

Mengendrossel
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Maintenance
SMD 2 / SMD 3
Set to bypass mode
Set to bypass mode - as described in 9.3
or 9.5
Loosen cover bolts and remove together
with plastic cover
Remove or clean existing gears
Carefully clean the gear chamber of depo-
sits and particles
SMD2
insert new gears in such a way that the
auxiliary holes point in the direction of
low meter housing
one of the gears bears a little metal shim.
With every rotation of the gear an impulse
is generated by the little metal shims
passing below the NAMUR switch.
The gear equipped with the little metal
shims must be inserted in such a way that
it sits under the NAMUR switch
SMD3
The gear equipped with the little metal
shims must be inserted in such a way that
it sits under the NAMUR switch
Change gasket
If necessary, replace the low meter
housing's o-ring seal
Mount cover
Place cover on the low meter's housing
Insert cover bolts in holes (SMD2 = 4x,
SMD3 = 6x)
Tighten cover bolts with a torque wrench
Tightening torque
SMD 2 = 5 Nm
SMD 3 = 8 Nm
Reset to normal operation
as described in 9.4 or 9.6
Page 67
closed gear face
closed gear face
Fig. 20 SMD 2
little metal Shim
Fig. 21 SMD 3