CA-800-Install.book Seite 32 Dienstag, 12. Februar 2008 3:34 15
Installation
✓ The first digit of the display (see fig. 8 on page 5, Pos. 5) shows the
menu level and the second and third show the parameter which can
be set.
➤ Press the + button (see fig. 8 on page 5, 6) once to switch to menu le-
vel 2.
➤ Press the operating mode button (see fig. 8 on page 5, Pos. 4) to
change the parameter.
✓ The digits in the display flash until the parameter you enter is confir-
med.
➤ Press the + or - buttons (see fig. 8 on page 5, Pos. 6 and 7) to select
the value for the low voltage cut-off. The ID number displayed in the
second and third place of the digital display stands for the voltage at
which the system is switched off.
ID
number
➤ Press the operating mode button (see fig. 8 on page 5, Pos. 4) to
confirm your entry.
✓ The set value is saved and is then used when the system is restarted.
✓ You are now in menu level 2 and can use the + and - buttons to switch
between menu levels.
6.3.4 Menu level 3: Operating mode
The system always starts with a defined operating mode for room tempe-
rature. This parameter can be configured:
➤ Start configuration mode (see chapter "Start and end configuration
mode" on page 30).
✓ The first digit of the display (see fig. 8 on page 5, Pos. 5) shows the
menu level and the second and third show the parameter which can
be set.
➤ Press the + button (see fig. 8 on page 5, 6) twice to switch to menu le-
vel 3.
➤ Press the operating mode button (see fig. 8 on page 5, Pos. 4) to
change the parameter.
✓ The digits in the display flash until the parameter you enter is confir-
med.
32
Low-voltage
cut-off
23,2
1
2
23,3
23,4
3
23,5
4
5
23,6
ID
Low-voltage
number
cut-off
23,7
6
7
23,8
23,9
8
24,0
9
10
24,1
CoolAir