Herunterladen Inhalt Inhalt Diese Seite drucken

Menu Level 2: Low Voltage Cut-Off - Waeco CoolAir RT880 Einbauanweisungen

Montagesatz für mercedes benz actros (sftp)
Vorschau ausblenden Andere Handbücher für CoolAir RT880:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation
6.3.3

Menu level 2: Low voltage cut-off

The battery monitor protects the battery from excessive discharging.
A
NOTICE!
When the battery monitor switches the device off, the battery only has
part of its charging capacity. Avoid starting repeatedly or operating elec-
trical consumers. Make sure that the battery is recharged. As soon as
the required voltage is available again, the unit can be operated again.
If only the set power supply is available here for the air conditioning roof
unit, the unit is switched off.
➤ Start configuration mode (chapter "Starting and ending configuration
mode" on page 46).
✓ The first digit of the display (fig. 0 5,page 8) shows the menu level
and the second and third show the parameter which can be set.
➤ Press the + button (fig. 0 6,page 8) once to switch to menu level 2.
➤ Press the Operating Mode button (fig. 0 4,page 8) to change the
parameter.
✓ The digits in the display flash until the parameter you entered is
confirmed.
➤ Use the + and – buttons (fig. 0 6 and 7, page 8) to set the value for
low voltage shutdown. The characteristic figures at second and third
place on the digital display represent the voltage (V) at which the unit
is shut down:
Characteristic
figure
➤ Press the Operating Mode button (fig. 0 4,page 8) to confirm your
entry.
✓ The set value is saved and is then used when the unit is restarted.
✓ You are now in menu level 2 again and can use the + and – buttons to
switch between menu levels.
48
Low voltage
shutdown
22.2
1
22.4
2
22.6
3
22.8
4
22.9
5
CoolAir RT880, SP950T
Characteristic
Low voltage
figure
shutdown
6
7
8
9
10
23.0
23.1
23.2
23.4
23.6
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis