7 Short start-up
Operating the panel
For selecting and adjusting
all parameters and signals.
0 L
Group
17 RAMP GENERATOR
and name
Subgroup
08 ACCEL 1
and name
20.0 s
Value
Selects the display of feedback values plus the
signal group and the error memory group.
ID number
Control
Speed
location
reference
of the
L = local
rpm
drive
selected
= remote
0 L
Status row
SPEEED ACT
Actual signal
name and value
CONV CUR
U ARM ACT
Cursor shows
the row selected
are used to change the group. In the parameter and
reference presetting modes, you can alter the param-
eter value or the reference setting ten times faster by
means of the twin arrow keys than by means of the
is used to select local (control
panel) or remote control.
Error acknowledgement key.
1 = last fault
0 L
2 = last-but-one fault
99 = last-but-98 fault
1 LAST FAULT
Name of Fault
Emergency stop
or alarm
Total time after
3212:59:35:56
switch-on
HHHH:MM:SS.ss
in local mode switches the main contactor on.
Panel (control and display panel)
The CDP 312 control and display panel commu-
nicates with the power converter via a serial
connection in accordance with the RS 485 stand-
ard at a transmission rate of 9.6 kBaud. It is an
option for the converter unit. After completion of
the commissioning procedure, the panel is not
necessarily required for diagnostic routines,
because the basic unit incorporates a 7-seg-
ment display for indicating errors, for example.
Parameters
0,0 rpm
00
Actual
Run status
Main contactor
status
1 = Run
0 = open
0 = Stop
1 = closed
0,0 rpm
00
0,0 rpm
0 A
0 V
Twin arrow keys
single arrow key.
Local/Remote
Reset
0,0 rpm
00
On
Function keys and various displays on the removable control and
display panel. The panel can also be used to load the same pro-
gram on different power converters.
I 14
3ADW000177R0222_DCS500B_QuickGuide_ru_b
Equipment
• 16 membrane pushbuttons in three function
groups
• LCD display comprising four lines with 20
characters each
• Language: German, English, French, Italian,
Spanish
Options for the CDP 312:
– cable, separated from the power converter
for utilization
– kit for mounting the panel in the switchgear
cubicle door
Function
Selects the "functions" operating mode; can be used
to perform special functions such as uploading and
downloading or application programming.
0 L
Status row
UPLOAD
Functions to be
selected
DOWNLOAD
Display contrast
CONTRAST
setting
Drive
for subsequent extensions
Enter
is used in the following modes:
Parameter setting:
enter new parameter value
Feedback value
signal display:
enter the current signal selec-
tion mode
Signal selection:
accept selection and return to
the feedback value signal dis-
play mode
Arrow keys
are used to select parameters within a group. You al-
ter the parameter value or the reference setting in the
parameter and reference presetting modes. In the
feedback signal display mode, you select the line you
want.
Start
starts the drive in local mode.
Stop
shuts the drive down if you are in local mode.
Reference
is used to activate the reference presetting mode.
Off
in local mode switches the main contactor off.
taken from/for further information:
System description
3ADW000066 - chapter 2
0,0 rpm
00
<==
==>