UK | 4 Safety instructions and warnings
Risk of death from carbon monoxide
when operating with air-ventilated
fireplaces. Ensure sufficient supply air intake
during operation with air-ventilated fireplaces.
Note maximum permissible pressure diffe-
rence per residential unit. The consent of a
professional chimney sweep is needed in all
cases.
Ventilation units may only be installed in
rooms, apartments or housing units of a com-
parable size, in which air-ventilated fireplaces
are installed if:
● a parallel operation of air-ventilated fire-
places for liquid or gaseous fuels and the
air-extracting equipment can be prevented
via safety devices, or
● the extraction of exhaust gas from the
air-ventilated fireplaces is monitored by
special safety equipment. In the case of
air-ventilated fireplaces for liquid or gaseous
fuels, the fireplace or the ventilation system
must be switched off if the safety device is
triggered. In the case of air-ventilated fire-
places for solid fuels, the ventilation system
must be switched off if the safety device is
triggered.
Exercise caution when handling
packaging materials.
Observe applicable safety and accident
prevention requirements.
Store packaging material out of the reach
of children (risk of suffocation).
5 Requirements of the installation
site
● Ambient temperature - 15 °C to + 40 °C.
● Airstream temperature max. 40 °C.
● Max. permissible humidity in installation
room 90 % (at 20 °C, noncondensing).
● A level and solid wall surface is needed for
wall installations.
● For filter changes, ensure sufficient space to
work in front of the unit.
32
● Do not drill core drill hole for unit assembly
and do not drill fixing points on external and
internal covers in load-bearing components,
such as in the lintel or ring beam.
6 Technical data
External diameter
Wall thickness
Wall sleeve
(max. length)
Air filter
Air volume/unit
Degree of protection
Sound pressure level,
at distance of 1 m
conditions without
obstructions (ventilation
level 1 to 5)
Rated voltage/
power frequency
Volumetric flow
heat recovery mode
ventilation level 1 to 5
Volumetric flow, exhaust
air mode (no heat
recovery)
Power consumption
(ventilation level 1 to 5)
Degree of heat provision 73.3 % (level 3)
SPI
SEC value
Permissible ducting
lengths with wired
connection
Weight slide-in module
cpl.
DN 160
320 - 790 mm
PP 45 RHK: 500 mm
PP 45 RHL 800 mm
G3 (2 pcs.)
26 m³/h
IP X4
18 / 32 / 41 /
45 / 49 dB(A)
230 V
50/60 Hz
5 / 12 / 18 /
22 / 26 m³/h
45 m³/h
1.7 / 2.5 / 3.4 /
4.4 / 5.3 W
0.19 W / (m³/h)
A (-39,71 kWh / (m²*a))
From star point max.
25 m per ventilation unit
3.6 kg