Technical data
Voltage
Mains frequency
Fuse
Power consumption
Connected load for appliance socket
Total connected load
Volume flow (air)
Negative pressure
Measurement area sound pressure level
at a distance of 1 m, EN 60704-1
Operating noise
Power cord: Length
Type
Protection class
Type of protection (splash water protected)
Radio interference level
Tank volume
Width × Depth × Height
Weight
Suction hose
Minimum air flow
diameter
volume
27 mm
690 l/min
32 mm
970 l/min
36 mm
1220 l/min
50 mm
2360 l/min
Accessories
Description
Filter bag (5 pcs.)
Waste bag (5 pcs.)
Filter element
Control elements
See page 3 of these operating instructions.
1. Handle with cable hook
2. Switch with suction power control
3. Retaining clamp
4. Dirt tank
5. Grip to empty tank
6. Inlet fitting
7. Tool socket
8. Hose diameter setting
9. Accessory holder
12
VCP 450 E-H
VCP 450 E-H AC
230 V
230 V
50/60 Hz
50/60 Hz
16 A
16 A
1200 W
1200 W
2400 W
2400 W
3600 W
3600 W
3600 l/min
3600 l/min
23 000 Pa
23 000 Pa
60 dB (A)
60 dB (A)
57 dB (A)
57 dB (A)
7.5 m
7.5 m
H05RR- F3G1,5
H05RR- F3G1,5
I
I
IP X4
IP X4
EN 55014-1
EN 55014-1
45 l
45 l
476 × 506 × 655 mm
476 × 506 × 655 mm
13 kg
14 kg
Associated negative pressure
between suction hose/tool
16 300 Pa
15 700 Pa
14 200 Pa
7800 Pa
VCP 450 E-H
VCP 450 E-H AC
Order No.
Order No.
639 903
639 904
626 436
626 436
625 372
639 906
Tests and approvals
The vacuum cleaners have been tested as specified
in IEC/EN 60335-2-69 including appendix AA. All the
requirements were fulfilled for equipment in dust
class H.
The vacuum cleaners must be inspected regularly in
accordance with national accident prevention regu-
lations.
A dust test must be performed at least once every
year by the manufacturer or a trained person. This
test covers, for example, whether there is damage
to the filter, the vacuum cleaner is sealed to the air
and the control equipment works properly.
GB