Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Limits - EBARA GMB GS Gebrauchs- Und Wartungsanleitung

Normpumpen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 87
Instruction and Maintenance Manual
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355

5. OPERATING LIMITS

Unless EBARA has been previously notified, in general, the equipment must be mounted
inside (below roof level), in adequately-ventilated rooms and where access is restricted
to authorised personnel, in addition to working within the following limits:
-
Ambient temperature: must not exceed 40°C and the average temperature over 24
hours must not be above 35°C. The minimum air temperature in the space will be 4°C.
-
Humidity: humidity must not exceed 50% and a temperature of 40°C. Higher humid-
ity levels can be accepted at very low temperatures.
-
Pollution: the air inside the aforesaid space must be clean and non-corrosive or,
failing that, the pollution level must be low and electrically non-conductive through
condensation.
-
Altitude: the altitude where the pump is installed must not exceed 1000 metres.
If the conditions of use are different from those indicated, EBARA must be notified of
these conditions; such as installation outdoors or in places open to the public; any
temperature, humidity, and altitude values other than those described; heavy pollution
due to dust, fumes, vapours or salt; exposure to strong magnetic or electrical fields;
locations exposed to risks of explosion, mechanical vibrations and significant shocks.
132
132
160
160
180
180
200
225
225
250
280
280
315
315
315
315
355
355
355
67
67
75
75
75
75
75
75
75
77
78
78
80
80
80
80
86
86
86
56
EN
56
67
67
67
67
70
70
70
70
73
73
77
77
77
77
84
84
84
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis