5.3. RESIDUAL RISKS
A residual risk of entering into contact (even if
not accidentally) with the rotor in the suction
port exists due to pump construction.
The residual risk exists in models with thermal
motor protection, that once the trip has activated,
the pump may restart without notice once the
motor has cooled to within the required operating
temperature limits.
6. DESCRIPTION AND USE
OF MOTOR-DRIVEN PUMP
6.1. DESCRIPTION
SUBMERSIBLE MOTOR-DRIVEN
Name
PUMPS
Model
DML-DMLV
(see Nameplate)
6.2. USE FOR WHICH PUMPS ARE DESIGNED
Motor-driven pumps are designed to:
-
Movement of water as described in paragraph 7.1
-
Movement of dirty or sewage water with solids in
suspension as described in paragraph 7.1;
-
Emptying cesspits, sceptic tanks, trenches, etc.
6.3. USE FOR WHICH PUMPS ARE NOT DESIGNED
Motor-driven pumps are not designed to:
-
pump liquids other than water;
-
pump water containing acids or alkalis, and corrosive
liquids in general;
-
pump seawater;
-
pump flammable liquids and hazardous liquids in
general;
-
enter into contact with food products;
-
be used in structures designed for living organisms
(pools, aquariums, fish farms, etc.);
-
be used in significantly important systems (computer
cooling or refrigeration systems, etc.):
-
be used in outdoor environments if equipped with
power cord under 10 m long;
-
be used for purposes other than those described in
Chapter 6.2 "Use for which pumps are designed".
The motor-driven pumps must never be made
WARNING!
to work without liquid.

7. SPECIFICATIONS

The manufacturer reserves the right to modify technical
specifications to improve or update its products without
prior notice.
7.1. SERIES-D PUMP TECHNICAL SPECIFICATIONS
PUMPED LIQUID SPECIFICATIONS
PH
Maximum liquid temperature
Free chloride concentration
Chloride ion concentration
DML/DMLV
Max solid
Delivery
dimension
Diameter/model
[mm]
DML
Ø 76
DMLV Ø80
Ø 80
DMLV Ø100
Ø 100
7.2. MOTOR SPECIFICATIONS
Motors on these pumps cannot be controlled by an inverter.
Frequency and voltage fluctuations are admitted for which
the sum of the relevant absolute value, with a maximum
±10% for voltage and ±1% for frequency, is equal to 10,
Electrical data
Overheating protection
- Motor protection
- Heat probe
Nr. starts per hour
- ≤ 7.5 kW
- >7.5 kW
Voltage tolerance
- ≤ 2.2 kW
- >2.2 kW
7.3 INFORMATION ON AIRBORNE NOISE
Given the type of use, the motor-driven pumps do not exceed
an A-weighted sound pressure emission level of 70 dB (A).

8. TRANSPORT, INSTALLATION AND DISMANTLING

On handling and installation work of the pump,
assure safety by confirming the mass and the
shape of the pump referring to the appearance
this instruction manual, drawing, the catalogue,
and other materials.
The handling and installation work of the pump
shall be done only by a qualified technician in
accordance with the applicable legal standards.
5 ÷ 9
0 ÷ 40°C
(without float)
≤ 10 mg/l
≤ 200 mg/l
Max fibre
Max
length
Submersion
[mm]
depth [m]
500
400
7
500
DML(V)
See Nameplate
≤2.2 kW
>2.2 kW
10
7
/
-10+6%
±10%
EN
9

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Dmlv 100Dmlv 80DlDvsDl w/cDmlv ... Alle anzeigen