6. After you have found the correct melting temperature, press
the sensor button "Silver". The temperature correction is
taken over as "Calibration offset".
The correction of the firing chamber temperature is completed.

6.6 Night Mode

This function switches the heating off automatically after firing
is complete and the chamber temperature drops to the night/
standby temperature. This function can be switched on or off for
the program as desired by pressing the "Bed" sensor button.
The "Bed" symbol for night mode is displayed in the firing curve.
After firing is complete, the furnace switches the display off and
the firing chamber cools down. After reaching the night/standby
temperature, the firing chamber closes automatically. The
night/standby temperature is maintained until the furnace is
switched on again. Pressing the "On/Off" sensor button switches
the Multimat2 Touch on again.

6.7 Select activation time

(sub-menu Configuration section 4.5.1)
This function automatically activates the furnace at a preselected
time. The function is set in the sub-menu "Configuration". The
input fields "Activate" and "Time" are displayed.
Setting the activation time
1. Press sensor button "M".
2. Press sensor button "Configuration".
3. Press sensor button "Time".
4. Enter the 24-hour time in the form 00:00 with the numeric
keypad.
5. Set sensor button "Activate" to "on".
6. Press sensor button "M" until the previous program is
displayed.
When switching the furnace off with the "On/Off" switch, it will be
automatically activated again at the preset time.
Note: For safety reasons, this function is active for only
24 hours. Therefore the sensor button "Activate" will switch
back to "Off" after automatic activation and must be manually
set to "On" again.

6.8 Vacuum test

(sub-menu Furnace parameters, section 4.5.2.2)
This test is for service purposes only.
58
6.9 Print/PC
Printing
The theoretical and actual values of a firing program are auto-
matically sent to a printer or PC after completion of the firing, if
the data output is set to "Printer" or "PC" in the basic settings.
The theoretical values for firing data can be printed out at any
time by pressing the button PR/PC. If no printer or PC symbol is
displayed, the data output is disabled.
The printer must be configured as follows (please see your
printer manual for directions):
9600 baud / 8 bit / 1 stop bit / no parity
Note: For printer/PC connection you will require:
• for serial connection:
1 "twin" cable, serial (D-SUB, 9, St/D-SUB, 9 jacks, 9 wires)
or
• for parallel connection:
1 serial to parallel connector, if a parallel printer is available.
Connect the printer with the Multimat2 Touch with the RS 232
interface.

6.10 Acoustic signals

Short signal:
At each key press
Long signal:
At invalid inputs
Triple signal:
At program end
In the pressing program:
insert material/furnace is preheated

6.11 Software update

In the scope of ongoing product maintenance, we recommend
always installing the newest software version for the Multimat2
Touch and Multimat2 Touch+Press products. Please ask your
field agent or simply download the newest software version from
the internet. The internet address is: www.digitux.de/dentsply.
Password: "tech".
The software of the Multimat2 Touch or Multimat2
Touch+Press is updated via the serial interface. Therefore,
please connect your Multimat2 with a serial cable to your PC.