and the wire marked in white to the white screw.
10. There is a wall mount on the back of the stove
transmitter. This can be pushed down and removed
from the stove transmitter.
11. Remove the cover from the stove transmitter and insert
the 3 x AA batteries with the correct polarity as marked.
Then you can slide the cover back on.
12. Look for a suitable location to attach the stove
transmitter and screw the wall bracket for the
transmitter into place. The stove transmitter should be
at least 50 cm away from the exhaust pipe so that the
transmitter cannot be destroyed by heat. Also the stove
transmitter should not be attached behind cladding as
this limit its range.

INITIAL OPERATION

Encoding
The exhaust control unit is encoded at the factory and
does not necessary need to be taught at initial
operation. If there are faults and/or function errors then
carry out the following encoding steps. This recreates
the structure of the exhaust controls.

Brief instructions

Factory settings

Press and hold the reset button
34
The unit will beep once after approx. 1 second and
4 green LEDs will flash.
There will be 3 beeps after another 7 seconds
followed by a pause and 3 more beeps. The
power LED will light constantly
Release the reset/learn button; the device is now
set to default
Teaching the sensors:
(All the sensors to be taught are ready for operation)
Briefly press the reset button on the central unit
1 beep will sound after approx. 1 second and the
4 green LEDs will flash
Now briefly press the set button on sensor 1
After approx. 10 seconds the LED will light
constantly depending on the sensor type
(window, roller shutter, stove contact) and will
beep once for sensor 1 and n times for sensor n
Press the set button on the next sensor within
50 seconds of the beep.
After the last sensor wait 50 seconds. The central
unit will go into default status and display the
condition of each sensor. The central unit is
ready for operation.
Logical associations:
Window closed
Window LED red
Window open
Window LED green
Stove on
Stove LED red
Stove off
Stove LED green
Roller shutter closed
Roller shutter LED red
Roller shutter open
Roller shutter LED green