WIRELESS EXHAUST AIR CONTROLLER AS-7000
Thank you for purchasing the PROTECTOR wireless
exhaust air controller in the A S7000 series.
The operating instructions are a constituent part of the
device. They contain important notes on safety, use
and disposal. Familiarise yourself with all the operating
and safety notes before using the device. Only use it as
described and for the given areas of use. Pass on all the
documentation if you transfer the device to a
third party.
GENERAL
The wireless exhaust air controller AS-7020/30/40 is
used in connection with exhaust air systems such as an
extractor hood, in rooms with access to an open fire,
gas heater, open fireplace, tiled stove, wood stove, oil
stove or similar.
Air is transported out of the room when using an
exhaust air system, e.g. an extractor hood or exhaust
air ventilators and this can cause negative pressure in
closed rooms.
When combustible material is burned in an open fire
this creates odourless and invisible carbon dioxide and
carbon monoxide gases. These gases can enter the
room from the fire when air is being removed with
the help of an exhaust air system and this can lead to
life-threatening poisoning in people in that room.
26
The exhaust air controller AS-7020/30/40 ensures
that an exhaust air system can only be operated when
fresh air is being supplied by an air supply system, e.g.
an open window, sufficient replenishment of fresh air.
The exhaust air controller AS-7020/30/40 only
switches the exhaust air device on if pressure
equalisation is ensured. The plug guard connects the
plug on the exhaust air device with the exhaust air
controller and prevents inadvertent connection of the
exhaust air device to an unprotected power source.
NOTE
The teaching of the sensors (window transmitter,
stove transmitter and roller shutter transmitter) in
connection with the central unit must be carried out
or tested before initial operation of the exhaust air
controller. If the exhaust air controller is installed
incompletely (e.g. without the relevant plug guard
in figure S) or if it has been taught incorrectly
before being connected to the socket a protect
function will be activated and it will not be possible
to operate the exhaust air system.
CAUTION!
The roller shutter must be open when the exhaust
air device is in use or it must be fitted with an
additional roller shutter sensor AS-R40. If the roller
shutter is closed it is not possible to ensure sufficient
replenishment of fresh air.