17 Technical data

Mains voltage/mains frequency:
Wattage:
Output for solenoid valve:
Length of mains lead:
Length of connecting lead:
Length of electrode cable:
Electrode connection:
Connection for connecting cable:
Measuring range:
Setting range:
Carbonate hardness range
for automatic pH setting:
Available hysteresis settings:
Splash-proof in accordance with IPX4
CE
18 Individual components - replacement parts
3089 pH-electrode
1445 pH 4 calibrating solution, 50 ml
1446 pH 7 calibrating solution, 50 ml
1447 Distilled water, 250 ml
1448 KCl solution, 50 ml
3080 CO
night cut-off valve Comfort
2
3091 Calibrating station
3094 pH-electrode holder

19 Warranty conditions

pH-Controller: 36 months
pH-electrode (wearing part): 12 months
Defective parts will be replaced or repaired free of charge during the warranty period, on condition that the equipment is used in the
proper manner for the intended purpose and the warranty card and receipt of purchase are sent to DENNERLE.
During the warranty period, the device may only be opened by DENNERLE's after sales personnel, otherwise the warranty coverage will
lapse. No claims shall be assertible beyond the value of the device, e.g. for damage to fish or plants.
34
230 V~ / 50 Hz
2 Watt + connected solenoid valve (max. 40 W)
230 V~, max. 40 W / 0,2 AT
3 m
3 m
3 m
BNC
SUB-d 9-polig
pH 3 - 9
pH 5,0 - pH 8,8
1-20 °d
0,01 – 0,05 – 0,1 – 0,15 - 0,2