GA EvolutionDeLuxe 1-06511-1107_GA pH ControllerEvol.Del. 13.06.2013 09:45 Seite 30
15
30
9.3 Setting the required CO
The CO
supply rate (CO
bubbles/minute) required to achieve the desired pH depends on a va-
2
2
riety of factors, such as the types of plants in the aquarium, motion of the water, surface area/vo-
lume ratio, etc. The appropriate CO
the specific aquarium concerned.
• Recommendation: Begin at approx. 10 bubbles per minute per 100 l of aquarium water, i.e.
2 x 10 = 20 bubbles per minute for a 200 l aquarium.
• After 1 day, check with the pH-Controller whether the desired pH value is achieved at this ra-
te and the device is able to perform its control functions in the correct manner, i.e. whether
the connected solenoid is switched off intermittently.
• If not, the number of bubbles should be increased to approx. 15 bubbles per minute per
100 l of aquarium water. Check again after 1 day. If necessary, increase the number of
bubbles further in small steps until the desired pH is attained.
Please observe the instructions for use of the employed CO
9.4
Table: Correlation between pH value,
CO
content and carbonate hardness
2

10 Special functions

10.1 Automatic pH setting
The "Auto" function enables the ideal CO
having to refer to the table:
• Press "Auto" key: The green LED flashes, the most recently set value appears on the display
(factory setting: 04). Enter the carbonate hardness measured in the aquarium with "+"
_
and "
".
• When the keys remain unused for 3 sec., this value will be adopted. The pH-Controller calcu-
lates the exact corresponding pH value automatically and sets the system accordingly. The LED
lights up in continuous mode.
• To check the set pH value: Press "pH" key: The set value appears on the display for 3 sec.
Example: Entered carbonate hardness 6 °d
The pH-Controller sets pH 7,0 automatically (= 20 mg/l CO
• To switch off the "Auto" function: Press "pH" key and then enter the new setting with "+" and
_
"
" while the green LED is flashing.
Setting range: Carbonate hardness 1 – 20 °d.
supply rate
2
supply level thus requires to be determined individually for
2
fertilizer system.
2
content (approx. 20 mg/l) to be set directly, without
2
).
2