13. FIRST OPERATION

Make sure that all stabilizers used during transport were removed.
 Check that all pressurized air line connections are secure.
 Connect to the mains.
 Start compressor at pressure switch (2) by turning switch (3) to position "I."(Fig.9)
 For cabinet-mounted compressors, turn the switch (26) in Fig. 4 on the front side of the equipment cabinet
into the "I" position; a lighted switch indicates the equipment is in operation.
 Compressor - At first operation the air tank is pressurized until it reaches a preset level when the
compressor automatically switches off.
As the air is used, the compressor works in automatic mode,
switched on or off by the pressure switch.
 Compressor with dryer – Compressor operation is the same and the moisture from the compressed air is
removed as it passes through the dryer.
For NDM - the condensate is also blown out of the drain on the dryer, which can be heard as a brief whoosh
sound when the compressor shuts down or when the drying chambers switch.
The compressor is not equipped with an emergency power supply.