Axovia 220B RTS
11.2.1. 1 set of photoelectric cells
TX
1
2
1
24 V
24 V
0 V
AC/DC
AC/DC
TX: Transmitter cell
RX: Receiver cell
11.2.2. 2 sets of photoelectric cells
TX2
TX1
1
2
1
2
24 V
0 V
24 V
0 V
AC/DC
AC/DC
AC/DC
TX: Transmitter cell
RX: Receiver cell
11.2.3. Recognition of the cells by the motor electronics
Cells are recognised either by reconfirming the motor's operating mode
(sequential or automatic, see "10. Advanced parameter setting"), or per-
forming auto-programming again (see "8.5. Gate travel self-learning").
11.2.4. If the cells are removed
If the cells are disconnected:
• in sequential mode, repeat the motor electronics cell recognition
procedure,
• in automatic closing mode, repeat the automatic closing mode ac-
tivation procedure.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
max. 20 cm
40 cm
RX
2
3
5
0 V C NO
RX
TX
RX
RX
RX1
RX2
1
2
3
5
1
2
3
5
24 V
0 V C NO
24 V
0 V C NO
AC/DC
11.2.5. Blocking cells
• If the cells are blocked when closing the gate, the gate will stop and
reverse its movement.
• If the gate is closed and the cells are blocked, the gate will not open.
11.3. Orange light
11.4. Exterior aerial
TX
11.5. Key lock
RX
Attention
This accessory is not compatible with solar power.
TX
TX
EN
5 mm
15 mm
12