WIRING THE ACCESSORIES
3
For your safety, these operations must be carried out with the power supply switched off.
You are advised to perform auto-programming of the gate travel before connecting the accessories (photoelectric cells, flashing light,
etc.)
3.1 Photoelectric cells
It is not possible to connect a second set of photoelectric cells on this motorisation.
Installation
A er wiring the photoelectric cells:
• switch the motor on again,
• start a gate opening or closing
procedure.
The photoelectric cells are recognised
by the control electronics once this
movement is complete.
Operation with
photoelectric cells
If the cells are blocked when closing the
gate, the gate will stop and reopen.
In the event of photoelectric cell disconnection
A er disconnection of the photoelectric cells, switch the motor on again and perform the procedure "Deactivating automatic closing", page
27.
3.2 Flashing light
10 W - 24 V bulb MAXIMUM - use of a bulb with power greater than 10 W- 24 V can
cause motorisation malfunctions.
Operation of the flashing light
The light flashes while the gate is moving.
3.3 Battery (depending on the pack chosen)
This accessory is not compatible with solar power.
To increase the operation time of the battery during use,
the wired controls are deactivated and the gate can only be
controlled using the remote controls and the radio control
points.
The backup battery ensures the operation of the gate in the
event of an electrical power failure.
The
indicator light flashes (1 pulse) when the motor is
battery-operated.
Battery technical data
• Battery life: 10 continuous cycles or 24 hours on a gate in perfect condition.
• Optimum charge time before using the battery: 48 hours.
• Service life: 3 years.
To ensure an optimum battery life, switch the gate's electric power supply off at least 3 times a year to run a number of cycles using the battery.
23
EN - EXAVIA installation and operating guide - SOMFY
TX
RX
1 2
1 2 3 5
TX
RX
1 2
1 2
1 2
or