Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of The Ethernet Cable; Telemetry Lines Connections - Videotec NXPTZT Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für NXPTZT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 251

7.1.5 Connection of the Ethernet cable

The operations described in this chapter
can only be performed in the versions with
a product network card.
Do not connect RS-485 cable and the video
cable when using an IP camera.
The multicore cable has 2 Ethernet B-type numbered
cables inside. Cable number 1 corresponds to the
IP output of the standard camera. Cable number 2
corresponds to the IP output of the thermal camera.
(if present).
Perform the connections following the instructions
reported in the table .
CONNECTION OF THE ETHERNET CABLE
Pin number
Cable color
1
Orange-White
2
Orange
3
Green-White
4
Blue
5
Blue-White
6
Green
7
Brown-White
8
Brown
Tab. 2
Both cables must be crimped in the same way.
The example below shows a typical installation.
Personal
Computer
Fig. 12
18

7.1.6 Telemetry lines connections

The cables allow access to 2 RS-485 serial
communication lines.
The lines can be configured in various ways according
to the dip-switch settings of the configuration board (
Fig. 16, page 20).
Telemetry lines connect the device to control and
programming units (keyboard or PC).
TELEMETRY LINES CONNECTIONS
Cable color
Yellow
Red
Blue
White
Black
Tab. 3
Switch
CDS installation type (Cable Distribution
System). The installation is type TNV-1, do
not connect it to SELV circuits.
Description
RS-485-1 line, A (+)
RS-485-1 line, B (-)
RS-485-2 line, A (+)
RS-485-2 line, B (-)
External washer tank level monitoring (if
present)
MNVCNXPTZT_1710_EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nxptz

Inhaltsverzeichnis