7.1.3 Connection of the power supply
line
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
When commencing installation make sure
that the specifications for the power supply
for the installation correspond with those
required by the device.
Check that the power supply socket and
cable are adequately dimensioned.
Depending on the version, the device can be
provided with different power supply voltages. The
power supply voltage is indicated on the product
identification label. (4.2 Product marking, page 11).
The multicore cable has the power and earth cables
inside.
Perform the connections following the instructions
reported in the table .
CONNECTION OF THE POWER SUPPLY LINE
Cable color
Power supply 24Vac
Black 2
Black 1
Yellow/Green
Power supply 230Vac
Black 2
Black 1
Yellow/Green
Power supply 120Vac
Black 2
Black 1
Yellow/Green
Tab. 1
MNVCNXPTZT_1710_EN
Description
~/24Vac
~/24Vac
GND/Earth
(N) Neutral
(L) Phase
Earth
(N) Neutral
(L) Phase
Earth
7.1.4 Connections of one or more video
cables
CDS installation type (Cable Distribution
System). The installation is type TNV-1, do
not connect it to SELV circuits.
The multicore cable has 2 black numbered video
coaxial cables inside. Cable number 1 corresponds
to the video output of the standard camera. Cable
number 2 corresponds to the video output of the
thermal camera. (if present).
17