Herunterladen Inhalt Inhalt Diese Seite drucken

A.1 I/O Connections And Wiring; Appendix A; I/O Connections And Wiring; Table A - Siemens SITRANS FUH1010 Betriebsanleitung

Flowmeter
Vorschau ausblenden Andere Handbücher für SITRANS FUH1010:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Appendix A

A.1

I/O Connections and Wiring

Terminal Block Wiring
(Refer to manual drawing 1010XS2-7 sheet 3 of 3. When Barriers are used, isolation is
limited to the Barrier's working voltage. Refer to table on manual drawing 1010-341 sheet 3).
These connection diagrams apply to the part numbers listed below.

Table A- 1

FUH1010
Table A- 2
Pin#
SITRANS FUH1010 Quick Start Guide
Operating Instructions, 1/2009, CQO:QSG009 Rev A

Part Numbers and Connection Diagrams

Menu Lockout Switch S1

FUH1010 Input/Output Wiring (TB1)

Signal
1
2
3
Io1 -
Isolated Loop Return
4
Io1 +
Isolated Loop Supply
5
ANIN -
Analog Input Return
6
ANIN +
4-20mA Input
7
Status -
Status Bit Return
8
Status +
Status Output
9
PGEN -
Pulse Generator Return
10
PGEN +
Pulse Generator Output
1010XS2-7 (Sheet 3 of 3) Drawing
7ME3601ab
where:
a= 0
b= D or F
Function
Not used on Single channel units.
Spannable 4-20mA output proportional to any
available data variable assigned under menu
control.
4-20mA input non-isolated (7ME3531-xF only)
Isolated Status Alarm Emiter
Isolated Status Alarm Collector
Isolated PGEN Emitter
Isolated PGEN Collector
A
Description
37