7.5 – CONTROL PROCEDURES
The entire appliance is controlled by an electronic circuit board.
As soon as the appliance is connected to the electricity supply, the whole display lights up for a "lamp-test" lasting a few
seconds, At the end of the lamp test, the display returns to the condition it was in before being switched off.
particular, if a cycle was in progress at the time, it will re-start from the point at which it was interrupted.
With the circuit board OFF the display is not lit except for the
the display and go into STANDBY mode; the cabinet temperature appears in blue on the display.
Use the controls on the panel, helped by the indications on the display, to activate the various appliance functions.
With the circuit board in STANDBY, pass from one cycle to another by simply pressing
With the circuit board in STANDBY and a cycle selected, start the cycle by pressing the
Similarly, press the
If the buzzer sounds for any reason whatsoever, it may be muted by simply pressing any button.
Whatever the appliance status, holding down the
7.6 – USE PROCEDURES
Before using the appliance, the inside of the cabinet should be thoroughly cleaned.
When switching on after installation or if the appliance has not been used for a long time, it is a good rule to let it operate
empty until the set temperature has been reached.
To get the best performance from the blast chiller, arrange the products so that air can circulate properly: do not obstruct
the fan, do not stack trays on top of each other, distribute the load neatly and do not cover the containers with lids or
cling film.
To avoid unwanted changes in the food, do not load the appliance with more than the allowed quantities, do not use
pieces thicker than 50-70 mm and avoid pointlessly opening the door.
Clean and sterilise the core probe before use. The probe must be inserted into the centre of the largest joint or piece,
taking care that the point does not go right through and come into contact with the tray.
To improve the efficiency of either the chill or freeze working cycle, we recommend pre-cooling the cabinet by
switching the appliance on at least 15 min before inserting the product.
When any cycle is selected the electronic circuit board checks the temperatures read by the cabinet sensor and
the core probe to assess correct insertion of the probe (AUTOMATIC probe acknowledgement). This check lasts
just over 2 minutes and then, in accordance with set parameters and provided the probe is properly inserted, a
temperature-controlled cycle starts. In this case the temperature of the core probe will be displayed and the icon
lights up.
A failed test is indicated by activation of the buzzer for one minute, after which the icon
display and a time-controlled cycle starts.
BCB_N Rev.05 05-2015
(STOP) button just once to stop the cycle in progress.
icon. Press the
button for 3 seconds puts the circuit board to OFF.
button to turn off the
icon on
,
.
(START) button once.
will light up on the
pag. 29
In