Herunterladen Inhalt Inhalt Diese Seite drucken

Parameter Description - Siko MA48 Benutzerinformation

Vorschau ausblenden Andere Handbücher für MA48:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Advancing the menu items:
via the
key.
Entering numerical values:
With numerical values, the smallest decade is the
first to blink. By pressing the
the value of the blinking digit. By pressing the
key you can advance to the next digit.
Changing a default selection:
Via the
key.
Display
Value range
LANGUAGE: ger (or deu) german
eng english
DEC:
0.; 0.0; 0.00; 0.000;
0.0000
DPR:
0...59999
DIVISOR:
1; 10; 100; 1000
INCR:
0...59999
DIRECTION: c; cc
INDEX:
I-lang; 0-lang; I-kurz;
0-kurz
TRS:
n.open; n.closed; hand Type of reference switch
REF:
-999999...+999999
OFF:
-999999...+999999
RESET:
off; on; del.1s; del.3s
MA48
Datum 01.06.2011
Taking over/saving the change:
Press the
played for a short time.

9. Parameter Description

key you can change
Having entered the programming mode (see chap-
ter 8) you can configure the parameters described
below. Depending on the settings chosen only the
menu items that are relevant for the application
will be shown.
Description
Language
Determines the language of the menu items.
Input of decimal places
Displayed value after one revolution
Value by which the display increases or decreases after exactly one revolu-
tion. With APU = 0, there is automatic quadruple evaluation of the encoder
signal.
Display divisor
Divisor by which the display accuracy is reduced compared to the measuring
accuracy. Example: Due to a non-integer value ratio, the measuring resolu-
tion is programmed to 1/1000mm. The display, however, needs a resolution
of 1/10mm only. -> Therefore, a display divisor of '100' is chosen.
Encoder pulses per revolution
If INCR: = 0, quadruple evaluation of the encoder signal takes place auto-
matically.
Counting direction of the measuring system
'c'' clockwise positive
'cc' counter-clockwise positive
Input of logic and length of the encoder's reference signal
The encoder reference signal is output only once per revolution.
'lang' index signal is wider than one increment; index is linked with A and
B signals.
'kurz' index signal is exactly as wide as one increment
'0' index signal with positive logic
'I' index signal with negative logic
Type of contact of the reference point encoder; can either be a mechanical
switch or a proximity switch.
'schlie.' normally open contact
'öffner' normally closed contact
'hand' referencing anywhere via keyboard ( independent of A, B, index sig-
nals). The input is earth-switching and edge-controlled.
Input of reference value
Reference point of the measuring system. The value is set when the system is
referenced according to chapter 6.
Input of offset value
Freely selectable value which influences the display. For example, offset can
be used as tool correction or offset measure
Enable reset function via asterisk key
'aus' reset function disabled
'ein' reset function enabled
'vz.1s' reset function enabled (by pressing the
'vz.3s' reset function enabled (by pressing the
Art.Nr. 85808
key; the "Save .." message will be dis-
-key for at least 1 sec.)
-key for at least 3 secs.)
Änd. Stand 193/11