4. Main Menu

Unicable settings (EN 50494)

1. Use the pq buttons to enter the line of the
port selection (see picture). Go with the t u
buttons on SATCR-50494 Port A and confirm
with OK to enter the Unicable settings.
2. Use the t u buttons to choose the band that
you want to measure (eg. 1). Switch with the
pq buttons to User Freq and click OK to con-
firm.
Note:
You can measure max. 8 bands on Unica-
ble (EN 50494).
3. Now enter the corresponding frequency of
the band. Use the pq buttons to change the
value, or the t u keys to select the next digit.
Confirm the entry with OK.
Note:
Please refer to the appropriate frequency
of your Unicable system.
WARNING:
The band must correspond necessarily with the frequency. Some manufacturers, the
band begins with No. 0 (1210 MHz), others with No. 1 (1210 MHz). Please make sure
when you enter the frequency in each band.
Unicable systems from Megasat
Unicable System
Band No.
1
2
3
...
10
Satmeter
Frequency
Band No.
0
1210 Mhz
1
1420 Mhz
2
1680 Mhz
...
...
Unicable systems from other manufacturers
Unicable System
Band No.
0
1
2
...
ENGLISH
Satmeter
Frequency
Band No.
0
1210 Mhz
1
1420 Mhz
2
1680 Mhz
...
...