Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring Of Digital Frequency Input / Digital Frequency Output - Lenze EVS9321 Montageanleitung

Vorschau ausblenden Andere Handbücher für EVS9321:
Inhaltsverzeichnis

Werbung

5
Electrical installation

Wiring of digital frequency input / digital frequency output

5.11
Wiring of digital frequency input / digital frequency output
Installation material required from the scope of supply:
Description
Protective cover
Technical data
Field
Connection at drive controller
Pin assignment
Output frequency
Signal
Load capacity
Special features
Internal voltage source
(X10/4, X10/5)
Field
Connection at drive controller
Input frequency
Signal
Signal evaluation
Current consumption
Special features
200
Use
Protection for unused Sub−D connections
Digital frequency output X10
Connector: Socket, 9−pole, Sub−D
Dependent on the selected basic configuration
0 ... 500 Nm
Two−track with inverse 5 V signals (RS422) and zero track
Max. 20 mA per channel
(up to 3 slave drives can be connected)
The "Enable" output signal at X10/8 switches to LOW if the drive
controller is not ready for operation (e.g. disconnected from mains). This
can trip SD3 monitoring on the slave drive.
DC 5 V / max. 50 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA
Digital frequency input X9
Connector: Pin, 9−pole, Sub−D
0 ... 500 kHz (TTL level)
Two−track with inverse 5 V signals (RS422) and zero track
Via code C0427
Max. 5 mA
With activated SD3 monitoring, TRIP or warning is tripped if the "Lamp
Control" input signal at X9/8 switches to LOW.
Due to this the drive controller can respond if the master drive is not ready
for operation.
l
Quantity
4
EDKVS9332X DE/EN/FR 4.0

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading