5
Electrical installation
Standard devices in the power range 0.37 ... 11 kW
Mains connection, DC supply
5.4.2
Mains connection, DC supply
)
Note!
ƒ
ƒ
Shield sheet installation
(
Stop!
ƒ
ƒ
M6
M5
Fig. 5−2
150
If a mains filter or RFI filter is used and the cable length between mains/RFI
filter and drive controller exceeds 300 mm, install a shielded cable.
For DC−bus operation or DC supply, we recommend using shielded DC
cables.
To avoid damaging the PE stud, always install the shield sheet and the PE
connection in the order displayed. The required parts are included in the
accessory kit.
Do not use lugs as strain relief.
0
1
2
3
4
5
6
7
Installation of shield sheet for drive controllers 0.37 ... 11 kW
0
PE stud
1
Screw on M5 nut and tighten hand−tight
2
Slide on fixing bracket for shield sheet
3
Slide on serrated lock washer
4
Slide on PE cable with ring cable lug
5
Slide on washer
6
Slide on spring washer
7
Screw on M5 nut and tighten it
8
Screw shield sheet on fixing bracket with two M4 screws (a)
l
a
a
1.7 Nm
}
L3 +UG -UG
L1
L2
15 lb-in
PE
M5
PE
3.4 Nm
30 lb-in
8
7
4
2
0
PE
+
9300vec130