n_soll_fest Anwahl
1 ... 2
p1016 (1)
n_soll_fest Bit 0
1
p1020 [C]
(0)
2
n_soll_fest Bit 1
1
p1021 [C]
(0)
2
n_soll_fest Bit 2
1
p1022 [C]
(0)
2
n_soll_fest Bit 3
1
p1023 [C]
(0)
2
1
2
Sollwertkanal
Drehzahlfestsollwerte, Binärauswahl (p1016 = 2)
0.000
[3011]
n_soll_fest 1 [rpm]
p1001 [D] (0.000)
n_soll_fest 2 [rpm]
[3011]
p1002 [D] (0.000)
n_soll_fest 3 [rpm]
p1003 [D] (0.000)
[3011]
n_soll_fest 4 [rpm]
p1004 [D] (0.000)
[3011]
n_soll_fest 5 [rpm]
p1005 [D] (0.000)
n_soll_fest 6 [rpm]
p1006 [D] (0.000)
n_soll_fest 7 [rpm]
p1007 [D] (0.000)
n_soll_fest 8 [rpm]
p1008 [D] (0.000)
n_soll_fest 9 [rpm]
p1009 [D] (0.000)
n_soll_fest 10 [rpm]
p1010 [D] (0.000)
n_soll_fest 11 [rpm]
p1011 [D] (0.000)
n_soll_fest 12 [rpm]
p1012 [D] (0.000)
n_soll_fest 13 [rpm]
p1013 [D] (0.000)
n_soll_fest 14 [rpm]
p1014 [D] (0.000)
n_soll_fest 15 [rpm]
p1015 [D] (0.000)
3
4
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
5
6
Funktionsplan
fp_3010_97_05.vsd
SINAMICS G120C
30.03.2015
V4.7.3
n_soll_fest wirk [rpm]
r1024
7
8
- 3010 -