Lenze 8200 motec Montageanleitung Seite 123

Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Code
No.
Name
C0088 Rated motor
current
C0089 Rated motor
frequency
C0090 Rated motor
voltage
C0091 Motor cos ϕ
C0119
Configuration
v
of motor
temperature
−12−
monitoring
(PTC input) /
earth fault
detection
C0140
Additive
*
frequency
setpoint
(NSET1−NADD
)
L
The most important codes for commissioning
Possible settings
Lenze
Selection
à
0.0
50
10
à
50
à
0.40
0
0
PTC input not
active
1
PTC input active,
TRIP set
2
PTC input active,
Warning set
3
PTC input not
active
4
PTC input active,
TRIP set
5
PTC input active,
Warning set
0.00 −650.00
EDK82MV222 DE/EN/FR 8.0
Commissioning
{0.1 A}
650.0
{1 Hz}
960
{1 V}
500
{0.1}
1.0
Earth fault
detection active
Earth fault
detection
{0.02
650.00
Hz}
IMPORTANT
à
Depending on the controller
0.0 ... 2.0 x rated output
current of the controller
à
230 V with 230 V controllers,
400 V with 400 V controllers
à
Depending on the controller
Signal output configuration
l
under C0415
l
If several parameter sets
are used, the monitoring
must be separately adjusted
for each parameter set.
l
Deactivate the earth fault
detection, if it has been
activated unintentionally.
If the earth fault detection is
l
active, the motor starts after
controller enable with a
delay of approx.40 ms.
Selection via function j
l
of the keypad or the
parameter channel
Is added to main setpoint
l
Value is stored when
l
switching the mains or
removing the keypad
7
121