Anleitung_BT_IW_100_SPK1__ 04.07.14 09:05 Seite 14
GB
connected to the negative pole. Ensure that you
observe the information supplied by the
manufacturer in relation to the type of electrode and
correct polarity. Fit the welding cables (8/9) to the
quick-lock couplings (5/6) accordingly. Then fasten
the unsheathed end of the electrode in the electrode
holder (8) and connect the ground terminal (9) to the
part you wish to weld. Ensure that a good electric
contact is made. Switch on the device and set the
welding current, depending on the electrode used,
using the potentiometer. Hold the safety shield in
front of your face and rub the tip of the electrode on
the part you wish to weld as if you were striking a
match. This is the best method of igniting an arc.
Check that you have the correct electrode and
current strength on a test part.
Electrode (Ø mm):
1,6
2
2,5
Important!
Do not dab the workpiece with the electrode since it
could be damaged, making it more difficult to ignite
the arc.
As soon as the arc has ignited, attempt to keep it a
distance from the workpiece equivalent to the
diameter of the electrode.
This distance should be kept as constant as possible
during the welding process. The angle of the
electrode in the direction in which you are working
should be 20/30°.
Important!
Always use tongs to remove spent electrodes and to
move parts that you have just welded. Please note
that the electrode holder (8) must always be put down
so that it is insulated after you have completed the
welding work.
Do not remove the slag until the weld has cooled.
If you want to continue a weld after an interruption,
the slag from your initial attempt must first be
removed.

9. Overheating guard

The welding set is fitted with an overheating guard
that protects the welding transformer from
overheating. If the overheating guard trips, the control
lamp (4) on your set will be lit. Allow the welding set to
cool for a time.
14

10. Maintenance

Remove dust and dirt from the machine at regular
intervals. Cleaning is best carried out with a fine brush
or a cloth.

11. Ordering replacement parts

Please quote the following data when ordering
replacement parts:
n
n
n
n
For our latest prices and information please go to
www.isc-gmbh.info
Welding current (A)
40 - 50 A
40 - 80 A

12. Disposal and recycling

60 - 110 A
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
13. Storage
Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing
temperature. The ideal storage temperature is
between 5 and 30 °C. Store the electric tool in its
original packaging.
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required