Troubleshooting
Malfunction
Cause
Fuse has blown; not
IS 240 DUO without power
y
switched on
Short-circuit
y
Twilight setting in night-
y
IS 240 DUO does
time mode during
not switch on
daytime operation
Bulb burned out
y
Power switch off
y
Fuse blown
y
Detection zone not
y
correctly adjusted
Continued movement
IS 240 DUO does
y
within the detection zone
not switch off
Switched on light is within
y
detection zone and swit-
ches on again as a result
of temperature change
Set to continuous
y
operation by indoor
series switch
Switched on light is
IS 240 DUO keeps
y
within detection zone
switching ON/OFF
Animals moving in
y
detection zone
Wind is moving trees
IS 240 DUO switches
y
and bushes in the
on when it should not
detection zone
Cars in the street
y
are detected
Sudden temperature
y
changes due to weather
(wind, rain, snow) or
exhaust air from fans or
open windows
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
18
Remedy
Replace fuse, switch on
y
mains switch, check
wiring with voltage tester
Check connections
y
Adjust setting
y
Replace light bulb
y
Switch on
y
Replace fuse, check
y
connection if necessary
Readjust
y
Check zone and readjust
y
if necessary or apply
shroud
Readjust zone or apply
y
shroud
Series switch to
y
automatic
Adjust detection zone or
y
apply shrouds, increase
distance
Adjust zone or apply
y
shrouds
Adjust zone or apply
y
shrouds
Adjust zone or apply
y
shrouds
Adjust detection zone or
y
install in a different place
Technical specifications
Dimensions (H x W x D):
90 x 60 x 100 mm
Output:
Filament bulbs,
1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max.,
at cos ϕ = 0.5, inductive load at 230 V AC
6 x 58 W each max.,
C ≤ 132 µF operating on 230 V AC
Connection:
230–240 V, 50 Hz
Angle of coverage:
240° (with 180° angle of aperture)
Pivoting range of the sensor:
Fine adjustment ± 80°
Reach:
max. 12 m (electronically stabilised)
Time setting:
10 sec. – 15 min.
Twilight setting:
2 – 2000 lux
Enclosure:
IP 54
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity of all connected
ballasts below the value specified).
Functional warranty
This STEINEL product has
This warranty shall not
been manufactured with
cover damage to wearing
great care, and its operation
parts or damage and faults
and safety have been tested
caused by incorrect opera-
in conformity with the current
tion or maintenance.
regulations. Production is
Breakage due to a fall is
also submitted to final
also not covered.
random-sample testing.
STEINEL undertakes the
Further consequential dam-
guarantee for perfect condi-
age to external items is
tion and function.
excluded.
The warranty period is 36
Claims under warranty shall
months, starting on the date
only be accepted if the
of sale to the user. We
product is sent fully assem-
undertake to remedy faults
bled and well packed com-
caused by material or manu-
plete with sales slip or
facturing defects. This war-
invoice (date of purchase
ranty undertaking shall be
and dealer's stamp) to the
performed by the repair or
appropriate Service Centre
replacement of the defective
or handed in to the dealer
parts, at our own discretion.
within the first 6 months.
*1)
Repair Service:
Our Customer Service
Department will repair faults
not covered by warranty or
after the warranty period.
Please send the product
well packed to your nearest
Service Centre.
19