13.7.8

Save Parameter in DME5000

The command "Download" in the window "Parameters" downloads the parameters to the
DME5000 and saves them there volatile.
The "Class Instance Editor" can be used to permanently store the parameters in the
DME5000 (for procedure, see screenshot).
 Description:
 Class:
 Instance:
 >Execute< message: Execution was completed.
13.7.9

Additional Diagnosis Data

The following parameters can be read as additional diagnosis data:
Reception level
 Description:
 Class:
 Instance:
 Attribute:
 Receive Data:
Save
65
1
Get single Attribute
64
1
11
Example: B0 → 0 x 100 – 0 x B0 = 0 x 47 → –71dB