Chapter 13
138
© SICK AG • Germany • Subject to change without notice
Annex
13.7.8
Save Parameter in DME5000
The command "Download" in the window "Parameters" downloads the parameters to the
DME5000 and saves them there volatile.
The "Class Instance Editor" can be used to permanently store the parameters in the
DME5000 (for procedure, see screenshot).
Description:
Class:
Instance:
>Execute< message: Execution was completed.
13.7.9
Additional Diagnosis Data
The following parameters can be read as additional diagnosis data:
Reception level
Description:
Class:
Instance:
Attribute:
Receive Data:
Save
65
1
Get single Attribute
64
1
11
Example: B0 → 0 x 100 – 0 x B0 = 0 x 47 → –71dB
Operating Instructions
DME5000
8009813/ZJV1/2017-05