Data Exchange

The type of data exchange is set in the window "Edit I/O Parameters":
5-byte data are sent, bytes 0 to 3 are the measured value, byte 4 the diagnosis data:
Byte
Position Value (low Byte Attribute 10)
0
Position Value
1
Position Value
2
Position Value (High-Byte-Attribute 10)
3
Laser on:
MF1
4
1
active: 1
Laser off:
MF1 not
0
active: 0
7
6
Warning:
All pre-failure messages are output as collective message here:
 Overtemperature
 Contamination
 Laser pre-failure message
Alarm:
Plausibility error signals that no measurement is possible; measured value "0" is output at
the same time.
13.7.4

Polled Mode

The process data exchange between DME5000 and DeviceNet-Master is by default
performed by a polled I/O connection. The slaves are cyclically targeted by the master.
© SICK AG • Germany • Subject to change without notice
MF2
Reserved
active: 1
by
DeviceNet
MF2 not
active: 0
5
4, 3, 2
Chapter 13
Warning: 1
Alarm: 1
No
No Alarm:
warning: 0
0
1
0
135